In brief

Fault code H6 on Gree Wall-mounted / Console means: Fault code H6 indicates that the electronic control board does not detect rotation of the indoor fan (no Hall sensor feedback). Most common cause: Fan wheel mechanically blocked (object, dust), faulty fan motor, or defective Hall effect sensor in the motor. First action: Push the fan wheel with a tool (power off): it should rotate freely.. Call a registered engineer if the fault returns after basic checks or involves refrigerant work (F-Gas registered engineer required).

According to the Gree Indoor Unit Service Manual, the H6 fault code is triggered when the PCB does not receive a speed feedback signal from the indoor fan motor.

H6GreeWall-mounted / Console

Fault Code H6 Gree: Anti-freeze / Defrost — Procedure

Fault code H6 indicates that the electronic control board does not detect rotation of the indoor fan (no Hall sensor feedback).

Source: Gree Indoor Unit Service Manual

Équipe Ask Marcel

Équipe Ask Marcel

Techniciens CVC certifiés

Rédaction et validation terrain par des installateurs PAC, clim et chauffage. Données croisées avec plus de 50 000 fiches pannes documentées.

What does fault code H6 on Gree mean?

Fault code H6 indicates that the electronic control board does not detect rotation of the indoor fan (no Hall sensor feedback).

Fan wheel mechanically blocked (object, dust), faulty fan motor, or defective Hall effect sensor in the motor.

Symptômes

  • No airflow
  • The louvre opens but nothing happens
  • Motor growling noise

Diagnostic

1. Manual rotation check

  • Push the fan wheel with a tool (power off): it should rotate freely.

2. Connector check

  • Check that the motor connector is securely clipped onto the PCB (it can become loose due to vibration).

How to reset fault code H6 on Gree?

Replace the fan motor.

When should you call an F-Gas engineer?

After cleaning filters with the fan wheel blocked by a mis-fitted filter, or a seized fan motor.

Affected models

  • Split Gree
  • Ducted

Field context

After cleaning filters with the fan wheel blocked by a mis-fitted filter, or a seized fan motor.

Technical source data

The H6 Gree fault concerns a defective indoor fan motor: no speed feedback signal to the PCB. Check fan wheel, motor and wiring before replacing the PCB.

Questions fréquentes

H6 Gree: motor or PCB first?

First check that the fan wheel rotates freely and that the motor is receiving power — H6 is a fan speed feedback fault.

Need help with this diagnosis?

Marcel reads your error codes and walks you through them step by step, with sourced answers.

Mobile app
Download on the App StoreGet it on Google Play

Or keep going right now in your browser:

Handling this fault code at scale? Plug AskMarcel into your own tools